©2007 Johnson Level & Tool
1
Automatic-Leveling Horizontal
Rotary Laser Level
Model No. 40-6535
Instruction Manual
Congratulations on your choice of this Automatic-Leveling Horizontal
Rotary Laser Level. We suggest you read this instruction manual
thoroughly before using the instrument. Save this instruction manual
for future use.
This is a Class IIIa laser tool and is manufactured to comply with CFR 21,
parts 1040 .10 and 1040 .11 as well as international safety rule IEC 285.
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1

©2007 Johnson Level & Tool1Automatic-Leveling Horizontal Rotary Laser LevelModel No. 40-6535Instruction ManualCongratulations on your choice of t

Strany 2 - 2. Features and Functions

10©2007 Johnson Level & ToolAdjust the inclination extent of the slopePressing the up/down arrow keys on the remote control, will adjust theinclin

Strany 3 - 3. Safety Instructions

©2007 Johnson Level & Tool11Detector Usage1. Product DescriptionA laser detector is an indispensable accessory when using this rotarylaser level.

Strany 4

8. Self-Check and CalibrationIMPORTANT: It is the responsibility of the user to verify the calibration of the instrument before each use.The instrumen

Strany 5 - Battery Cover

X-direction self-check with the same method as Y-directionself-check, and mark point C and point D by turns.7. If point C and point D are within 1/32”

Strany 6 - 6. Operating Instructions

14©2007 Johnson Level & ToolAdjust laser beam to reference positionPress the up/down arrow buttons on the remote con-trol to adjust the laser bea

Strany 7 - Alkaline Battery Installation

©2007 Johnson Level & Tool15Confirm calibration valuePress ‘ENT’ button on the remote control toconfirm self-calibration value. The Ydirection sel

Strany 8 - 7. Using the Product

16©2007 Johnson Level & Tool10. Application DemonstrationsSquaring LevelingGradingSet FormsElevation

Strany 9 - 2. Adjust the slope angle

©2007 Johnson Level & Tool1711. Care and Handling• This laser unit is a precision tool that must be handled with care.• Avoid exposing unit to sho

Strany 10

18©2007 Johnson Level & Tool12. Product WarrantyJohnson Level & Tool offers a one year limited warranty on each itsproducts. You can obtain a

Strany 11 - 2. Technical Specifications

©2007 Johnson Level & Tool1913. Product RegistrationEnclosed with this instruction manual you will find a warranty card to becompleted for product

Strany 12 - 8. Self-Check and Calibration

2©2007 Johnson Level & ToolTable of Contents 1. Kit Contents2. Features and Functions3. Safety Instructions4. Location/Content of Warning Labels5.

Strany 13

20©2007 Johnson Level & Tool

Strany 14

©2007 Johnson Level & Tool33. Safety Instructions Please read and understand all of the following instructions, prior to using this tool. Failure

Strany 15 - 9. Technical Specifications

4©2007 Johnson Level & Tool4. Location/Content of Warning Labels

Strany 16 - Elevation

©2007 Johnson Level & Tool55. Location of Part/ComponentsRotating laser emitting windowHandleKeypadDC 6VBattery Cover

Strany 17 - 11. Care and Handling

6©2007 Johnson Level & Tool6. Operating InstructionsIMPORTANT: It is the responsibility of the user to verify the calibration of the instrument be

Strany 18 - 12. Product Warranty

©2007 Johnson Level & Tool7Note:(1) For the first two charges of new rechargeable batteries, it is necessary to charge for 12 plus hours.(2) The u

Strany 19 - 14. Accessories

8©2007 Johnson Level & Tool7. Using the ProductOperating PanelPower On/Off1. Press the power button to power on. Thepower indicator lamp will ligh

Strany 20

©2007 Johnson Level & Tool9Height of Instrument (H.I.) - TILT1. After powering on the instrument and entering intoauto-level status, press the til