TABLE B
Change Decimals to Fractions
.06" =1/16" .56" =9/16"
.13" =1/8" .63" =5/8"
.19" =3/16" .69" =11/16"
.25" =1/4" .75" =3/4"
.31" =5/16" .81" =13/16"
.38" =3/8" .88" =7/8"
.44" =7/16" .94"=15/16"
.50" =1/2"
SOLAR PANEL SUPPORT EXAMPLE
Let us build a rafter support for a series of flat plate
collectorsonasouth-facing8-inchriseroof.
STEP 1. RAFTER CALCULATIONS: The pitch for the
support rafters, which is really the desired tilt angle for
the solar panels, will be needed. If known in degrees,
convert it to the nearest inch rise so that the tables may
beused.Thispitchisfoundbyadding10to15degrees
toyourlatitude(sincethisistheoreticallythebestfor
heating).Inourexample,weneeda58°pitchora19
inchrisebecausethelatitudeofMilwaukeeis43°.(See
Table C, page 39). The angle of tilt is not critical, since
the eciency is not appreciably reduced by a small dif-
ference in tilt angle from optimum, thus the closest inch
risecanbeused(seeFigures20and21).